AA Solar 4 Blue Gum Avenue SILVERDALE, AUCKLAND 0932 NEW ZEALAND Phone: 09 427 4040 or 09 427 4143 Fax: 09 427 4040 Cell: 0274 905 901 Email: sales@aasolar.co.nz Web: www.aasolar.co.nz |
|||||||
| Home | Products |
Prices |
Frequently Asked Questions |
Contact Us |
SunPowerPlus Webpage |
SunPowerPlus
TradeMe
Site |
|
Pure Sinewave Inverters and Inverter/Chargers |
|
|||||||||||
HP-COMPACT Sinewave Inverter-Charger |
|||||||||||
|
Models
available:-
HPC
2800-122500 watt continuous
12V
HPC 4400-24 4000 watt continuous 24V HPC 8000-48 7000 watt continuous 48V |
The
Studer HP-Compact Pure
sinewave inverter/charger can be used in houses, motor homes, and
boats, and can be used for running a wide selection of appliances,
including washing machines, fridges, computers, televisions, toasters,
kettles, pumps, power
tools, and lights. The HP Compact Inverter-Charger units offer 3 fully automatic functions:-
|
||||||||||
| Model | HPC 2800-12 | HPC 4400-24 | HPC 8000-48 |
| Inverter |
|||
| Nominal Battery Voltage | 12V | 24V | 48V |
| Input
Voltage Range |
9.5
-
17
V |
19
-
34
V |
38
-
68
V |
| Continuous Power @ 25°C | 2500VA |
4000VA |
7000VA |
| Power 30 min @ 25°C | 2800VA |
4400VA |
8000VA |
| Maximum Power Load 5 sec | 3 x Pnom | ||
| Maximum Load | Up to short circuit | ||
| Maximum Asymmetric Load | Up to Pcont | ||
| Stand-By Adjustment | 1 to 25 watt | ||
| Cos φ | 0.1—1 |
||
| Maximum Efficiency | 93% |
94% |
96% |
| Consumption OFF/Stand-By/ON | 1.4/1.8/10W |
1.7/2/16W | 2/3/30W |
| Output Voltage | 230Vac
(-10%/0) |
||
| Output Frequency Crystal Controlled | 50Hz
± 0.05% |
||
| Total Harmonic Distortion | <
2% |
||
| Dynamic Behaviour on Load Change 0 to 100% | 0.5
ms |
||
| Overload and short circuit protection | Automatic
Disconnection with 3 time restart attempt |
||
| Overheat Protection | Acoustic
warning before shut-off—with automatic restart |
||
| Battery
Charger
(4
STEP)
I-U-Uo-Equalize
(every
25
cycles) |
|||
| Charging
Current Adjustable |
0-110A | 0—100A |
0—90A |
| Input
Current Balance Adjustment (Power Sharing) |
1—30A |
1—50A |
|
| Maximum
Input Voltage |
265
Vac |
||
| Minimum
Input Voltage |
Adjustable
Threshold from 150 to 230Vac |
||
| Input
Frequency |
45—65
Hz |
||
| Power
Factor Correction (PFC) |
EN
61000-3-2 |
||
| Battery
Control
(thresholds
and
times
adjustable
by
the
user) |
|||
| Absorption Time | 0—4 hr | ||
| End
Charge Cycle Voltage |
14.4 V | 28.8 V | 57.6 V |
| Floating
Voltage |
13.6
V |
27.2
V |
54.4
V |
| Equalization
Voltage |
15.6
V |
31.2
V |
62.4
V |
| Deep-Discharge
Protection |
10.8
V |
21.6
V |
43.2
V |
| Temperature Compensation (optional CT-35) | -3mV / ° C / cell | ||
| General
Data |
|||
| Multifunction Contact—Potential Free (3 points) | 16A—250
Vac |
||
| Max.
Current on Transfer Relay |
30A/6.9kVA | 50A/11.5kVA |
|
| Transfer Time | <
20 ms |
||
| Weight |
33kg |
39kg |
45kg |
| Dimension:
D x W x H (mm) |
242
x 288 x 480 |
242 x 288 x 480 | 242 x 288 x 500 |
| Protection
Index IP20 |
IP23 |
||
| EC
Conformity |
EN61000-6-1,
EN61000-6-3, EN55014,EN55022,EN61000-3-2 Dir. 89/336/EEC, LVD 73/23/EEC |
||
| Operating
Temperature Range |
-20
to 55° C |
||
| Ventilation |
From
45° C |
||
| Acoustic
Level Without / With Ventilation |
<
10dB / < 35dB |
||
| Warranty |
2
years |
||
| Data
subject
to change without prior notice |
|||
| Accessories |
|||
ARM-01 |
Auxilliary Relay Module |
![]() |
|
CT-35 |
Temperature Sensor |
![]() |
|
RCC-01 |
Remote Controller c/w 20m cable |
![]() |
|
RPS 01 |
Remote Power Sharing |
![]() |
|
|
Sinewave
Inverter-Charger |
![]() |
|||||||
|
Models available:- XPC 1400-12
1100 watt continuous
12V
XPC
2200-24 1600 watt continuous 24V |
|
The Studer XP-Compact Pure sinewave inverter/charger can be used in houses, motor homes, and boats, and can be used for running a wide selection of appliances, including washing machines, fridges, computers, televisions, toasters, kettles, pumps, power tools, and lights.
The XP COMPACT benefits from our "one step ahead" technology in the field of inverters. THE XP COMPACT SERIES OFFER:
|
||||||
| Model | XPC 1400-12 | XPC 2200-24 |
|
|
||
| Inverter |
||
| Nominal Battery Voltage | 12V | 24V |
| Input
Voltage Range |
9.5
-
16
V |
19
-
32
V |
| Continuous Power @ 25°C | 1100VA |
1600VA |
| Power 30 min @ 25°C | 1400VA |
2200VA |
| Maximum Power Load 5 sec | 3 x Pnom | |
| Maximum Load | Up to short circuit | |
| Maximum Asymmetric Load | Up to Pcont | |
| Stand-By Adjustment | 1 to 25 watt | |
| Cos φ | 0.1—1 |
|
| Maximum Efficiency | 94% |
95% |
| Consumption OFF/Stand-By/ON | 0.5/0.6/4W |
0.8/0.9/7W |
| Output Voltage | 230Vac
(-10%/0) |
|
| Output Frequency Crystal Controlled | 50Hz
± 0.05% |
|
| Total Harmonic Distortion | <
4% |
<
2% |
| Dynamic Behaviour on Load Change 0 to 100% | 0.5
ms |
|
| Overload and short circuit protection | Automatic
Disconnection with 3 time restart attempt |
|
| Overheat Protection | Acoustic
warning before shut-off—with automatic restart |
|
| Battery
Charger
(4
STEP)
I-U-Uo-Equalize
(every
25
cycles) |
||
| Charging
Current Adjustable |
0-45A | 0—37A |
| Input
Current Balance Adjustment (Power Sharing) |
n.a. |
|
| Maximum
Input Voltage |
265
Vac |
|
| Minimum
Input Voltage |
Adjustable
Threshold from 150 to 230Vac |
|
| Input
Frequency |
45—65
Hz |
|
| Power
Factor Correction (PFC) |
EN
61000-3-2 |
|
| Battery
Control
(thresholds
and
times
adjustable
by
the
user) |
||
| Absorption Time | 0—4 hr | |
| End
Charge Cycle Voltage |
14.4 V | 28.8 V |
| Floating
Voltage |
13.6
V |
27.2
V |
| Equalization
Voltage |
15.6
V |
31.2
V |
| Deep-Discharge
Protection |
10.8
V |
21.6
V |
| Temperature Compensation (optional CT-35) | -3mV / ° C / cell | |
| General
Data |
||
| Multifunction Contact—Potential Free (3 points) | 16A—250
Vac |
|
| Max.
Current on Transfer Relay |
16A/3.7kVA | |
| Transfer Time | <
20 ms |
|
| Weight |
11.7kg |
12.6kg |
| Dimension:
D x W x H (mm) |
124
x 215 x 410 |
124
x 215 x 410 |
| Protection
Index IP20 |
IP23
with top cover C-IP23 |
|
| EC
Conformity |
EN61000-6-1,
EN61000-6-3, EN55014,EN55022,EN61000-3-2 Dir. 89/336/EEC, LVD 73/23/EEC |
|
| Operating
Temperature Range |
-20
to 55° C |
|
| Ventilation |
From
45° C |
|
| Acoustic
Level Without / With Ventilation |
<
10dB / < 35dB |
|
| Warranty |
2
years |
|
| Data
subject
to change without prior notice |
||
| Accessories |
|||
ARM-01 |
Auxilliary Relay Module |
![]() |
|
CT-35 |
Temperature Sensor |
![]() |
|
RCC-01 |
Remote Controller c/w 20m cable |
![]() |
|
AJ Series Sinewave Inverters |
![]() |
| Models
available:- AJ275-12 200 watt continuous
12V
AJ350-24 300 watt continuous 24V AJ500-12 400 watt continuous 12V AJ600-24 500 watt continuous 24V AJ1000-12 800 watt continuous 12V AJ1300-24 1100 watt continuous 24V AJ2100-12 2000 watt continuous 12V AJ2400-24 2000 watt continuous 24V |
The AJ series offer:
|
||
| Model |
AJ275-12 |
AJ350-24 |
AJ500-12 |
AJ600-24 |
AJ1000-12 |
AJ1300-24 |
AJ2100-12 |
AJ2400-24 |
| Battery
Voltage
(V) |
12 |
24 |
12 |
24 |
12 |
24 |
12 |
24 |
| Input
Voltage (V) |
10.5
- 16 |
21
- 32 |
10.5
- 16 |
21
- 32 |
10.5
- 16 |
21
- 32 |
10.5
- 16 |
21
- 32 |
| Power:
continuous (VA) |
200 |
300 |
400 |
500 |
800 |
1000 |
2000 |
2000 |
| Power:
30 mins (VA) |
275 |
350 |
500 |
600 |
1000 |
1300 |
2100 |
2400 |
| Stand-by/ON
no load (W) |
0.3/1.9 |
0.3/3.3 |
0.3/3.8 |
0.4/8.5 |
0.3/9 |
0.4/10 |
0.5/13 |
0.4/18 |
| Max
efficiency (%) |
93 |
94 |
93 |
94 |
93 |
94 |
92 |
94 |
| Dimensions:
142 x 84 x L (mm) |
163 |
240 |
428 |
276 x 399 x 117 |
||||
| Weight
(kg) |
2.4 |
2.6 |
4.5 |
8.5 |
19 |
18 |
||
| Remote
Control ability |
Option | Yes | ||||||
| Load
Detection Standy-By |
No |
Yes | ||||||
| Protection
index |
IP30 |
IP20 |
||||||
| Data subject to change without prior notice | ||||||||
![]() |
Remote Control JT 8 for 800 to 2000 watt models |
|||||||
SI Series Sinewave Inverters |
| Models
available:-
SI1212TP 1200 watt continuous 12VDC with TwinPower option SI3324TP 3300 watt continuous 24VDC with Twinpower option |
The SI series offer::-
|
||
| Model |
SI 1212TP |
SI
3324TP |
| Battery
Voltage
(V) |
12 |
24 |
| Power:
continuous (VA) |
1200 |
3300 |
| <<Stand-by>>
current mA Power << ON >> no load (W) |
25 4.8 |
25 13 |
| Power << ON >> no
load
(W) TWINPOWER system |
< 0.5 |
< 0.7 |
| Max
efficiency (%) |
93 - 95 |
95 |
| Dimensions:
(mm) |
391L x 124H
x 215W |
636L
x 124H x 215W |
| Weight
(kg) |
13.2 |
30 |
| Input
Voltage |
Min
- Max: < Unom x 0.95 to Unom x 1.33 |
|
| Dynamic
correction of Umin |
-
10% at Pnom |
|
| Output
voltage |
True
sine 230VAC ± 3% |
|
| Distortion |
<
2% at Pnom |
|
| Dynamic
behaviour |
From
0% to 100% load change. Normalization: 0.5 ms |
|
| Frequency |
50
Hz ± 0.01% (Crystal control) |
|
| Load detection (stand-by) |
Adjustable:
0.3 - 20W |
|
| Maximum
power 15 min |
1.3
- 1.6 x Pnom / 25°C |
|
| Maximum
power 3 min |
1.6 - 2 x Pnom / 25°C | |
| Peak
power 5 sec |
3.5
x Pnom |
|
| Asymmetric
load |
Up
to 2 x Pnom |
|
| Cos φ | 0.1
- 1 |
|
| Protections |
Overload/Overheat/Short-circuit/Reverse
polarity
by
internal
fuse |
|
| IP
protection index |
IP20
complies with DIN 40050/IP 23 with top cover C-IP23 |
|
| Forced
ventillation |
From 45°C ± 3°C | |
| Overheating
protection |
75°C ± 3°C | |
| Required
battery capacity |
>
5 x Pnom/Unom (recommended value) |
|
| Acoustic
level |
With
ventilation: < 10
dB
Without
ventilation:
<
35
dB |
|
| EC
conformity |
EN61000-6-1,
EN61000-6-3, EN55014, EN55022, EN61000-3-2, Dir. 89/336/EEC, LVD 73/23/EEC |
|
| Data subject to change without prior notice | ||
| Model | C1600-12 |
C2600-24 |
|
|
||
| Inverter |
||
| Nominal Battery Voltage | 12V | 24V |
| Input
Voltage Range |
9.5
-
16
V |
19
-
32
V |
| Continuous Power @ 25°C | 1300VA |
2300VA |
| Power 30 min @ 25°C | 1600VA |
2600VA |
| Maximum Power Load 5 sec | 3 x Pnom | |
| Maximum Load | Up to short circuit | |
| Maximum Asymmetric Load | Up to Pcont | |
| Stand-By Adjustment | 1 to 25 watt | |
| Cos φ | 0.1—1 |
|
| Maximum Efficiency | 94% |
95% |
| Consumption OFF/Stand-By/ON | 0.5/0.6/6W |
0.8/0.9/9W |
| Output Voltage | 230Vac
(-10%/0) |
|
| Output Frequency Crystal Controlled | 50Hz
± 0.05% |
|
| Total Harmonic Distortion | <
2% |
|
| Dynamic Behaviour on Load Change 0 to 100% | 0.5
ms |
|
| Overload and short circuit protection | Automatic
Disconnection with 3 time restart attempt |
|
| Overheat Protection | Acoustic
warning before shut-off—with automatic restart |
|
| Battery
Charger
(4
STEP)
I-U-Uo-Equalize
(every
25
cycles) |
||
| Charging
Current Adjustable |
0-55A | 0—55A |
| Input
Current Balance Adjustment (Power Sharing) |
1—16A |
|
| Maximum
Input Voltage |
265
Vac |
|
| Minimum
Input Voltage |
Adjustable
Threshold from 150 to 230Vac |
|
| Input
Frequency |
45—65
Hz |
|
| Power
Factor Correction (PFC) |
EN
61000-3-2 |
|
| Battery
Control
(thresholds
and
times
adjustable
by
the
user) |
||
| Absorption Time | 0—4 hr | |
| End
Charge Cycle Voltage |
14.4 V | 28.8 V |
| Floating
Voltage |
13.6
V |
27.2
V |
| Equalization
Voltage |
15.6
V |
31.2
V |
| Deep-Discharge
Protection |
10.8
V |
21.6
V |
| Temperature Compensation (optional CT-35) | -3mV / ° C / cell | |
| General
Data |
||
| Multifunction Contact—Potential Free (3 points) | 16A—250
Vac |
|
| Max.
Current on Transfer Relay |
16A/3.7kVA | |
| Transfer Time | < 40 ms |
|
| Weight |
16kg |
17.1kg |
| Dimension:
D x W x H (mm) |
124 x 215 x 480 |
|
| Protection
Index IP20 |
IP20
(IP23 with top cover C-IP23) |
|
| EC
Conformity |
EN61000-6-1,
EN61000-6-3,
EN55014,EN55022,EN61000-3-2
Dir.
89/336/EEC,
LVD
73/23/EEC |
|
| Operating
Temperature Range |
-20
to 55° C |
|
| Ventilation |
From
45° C |
|
| Acoustic
Level Without / With Ventilation |
<
10dB / < 35dB |
|
| Warranty |
2
years |
|
| Data
subject
to change without prior notice |
||
| Accessories |
|||
ARM-01 |
Auxilliary Relay Module |
![]() |
|
CT-35 |
Temperature Sensor |
|
|
RCC-01 |
Remote Controller c/w 20m cable |
|
|
RPS 01 |
Remote Power Sharing |
![]() |
|
| Model |
XTH3000-12 |
XTH5000-24 |
XTH8000-48 |
| Inverter | |||
| Nominal Battery Voltage |
12 |
24 |
48 |
| Input voltage range V |
9.5 - 17 |
19 - 34 |
38 - 68 |
| Continuous
Power
@
25°
C |
2500 VA |
4000 VA |
7000 VA |
| Power Smart-Boost |
2500 VA |
4000 VA |
7000 VA |
| Power 30 min @ 25° C | 3000 VA |
5000 VA |
8000 VA |
| Power 5 sec @ 25° C | 3 x Pnom |
||
| Maximum Load |
Up to short circuit |
||
| Maximum asymmetric load |
Up to Pcont. |
||
| Load Detection (stand-by) |
2 to 25 W |
||
| Cos φ | 0.1 - 1 |
||
| Maximum Efficiency |
93 % |
94% |
96% |
| Consumption OFF/Stand-by/ON |
1.7W / 2.2W
/ 14W |
1.8W / 2.5W
/ 20W |
2.2W / 3W /
34W |
| Output Voltage |
Sine Wave 230Vac
(+0/- 10%) / 190-245 Vac |
||
| Output Frequency |
50 Hz adjustable 45 -
65 Hz ± 0.05% (crystal controlled) |
||
| Harmonic Distortion |
< 2% |
||
| Dynamic Behaviour |
0.5 ms (on load
change 0 to 100%) |
||
| Overload and Short Circuit
Protection |
Automatic
disconection with 3 time restart attempt |
||
| Overheat Protection |
Warning before
Shut-off with Automatic Restart |
||
| Battery
Charger
6
Step
Adjustable:
I-U-Uo-Equalize-Uo(low)-U(periodic) |
|||
| Charging Current Adjustable |
0 - 160 A |
0 - 140 A |
0 - 120 A |
| Input Current Balance Adjustment |
1 - 30 A |
1 - 50 A |
|
| Maximum Input Voltage |
265 Vac |
||
| Input AC Voltage Range |
Adjustable threshold
from 150 to 230 Vac |
||
| Input Frequency |
45 - 65 Hz |
||
| Power Factor Correction (PFC) |
EN61000-3-2 |
||
| Detection of Short-Circuited
Battery Cell |
√ |
√ | √ |
| Battery
Control |
|||
| Absorption end |
By duration 4 / 0.25
10 h or by current / 4 - 30 A |
||
| Absorption Voltage | 14.4 / 9.5 -
18 V |
28.8 / 19 -
36 V |
57.6 / 38 -
72 V |
| Periodic Absorption Voltage |
- / 9.5 - 18
V |
- / 19 - 36 V |
- / 38 - 72 V |
| Floating Voltage |
13.6 / 9.5 -
18 V |
27.2 / 19 -
36 V |
54.4 / 38 -
72 V |
| Reduced Floating Voltage |
- / 9.5 - 18
V |
- / 19 - 36 V |
- / 38 - 72 V |
| Equalization |
Ny number of cycles
(- / 1 - 100) or set interval (- / 52 weeks) |
||
| Equalization end |
By duration 4 / 0.25
- 10h or by current - / 4 - 30 A |
||
| Equalization Voltage |
- / 9.5 - 18
V |
-/19-36 V |
- / 38 - 72 V |
| Deep-Discharge Protection |
10.8 / 9.5 -
18 V |
21.6 / 19 -
36 V |
43.2 / 38 -
72 V |
| Reduced Floating Time |
- / 0 - 32 days |
||
| Periodic Absorption Time |
- / 0 - 10 hours |
||
| Temperature Compensation
(optional BTS-01) |
-5 / 0 to -8mV/ °
C / cell |
||
| General
Data |
|||
| Multifunction Contact Adjustable |
2 independent contacts 16A 25- Vac (potential free 3 points) | ||
| Max. current on Transfer Relay |
30A / 6.9kVA |
50A / 11.5kVA |
|
| Transfer Time |
< 20ms |
||
| Weight |
34 kg |
40 kg |
46 kg |
| Dimension H x D x L (mm) |
220 x 290 x 500 |
220 x 310 x
500 |
|
| Protection Index |
IP23 |
||
| Conformity |
EN61000-6-1,
EN61000-6-3,
EN55014,
EN55022,
EN61000-3-2,
Dir.89/336/EEC,
LVD
73/23/EEC |
||
| Operating Temperature Range |
-20 to 55 ° C | ||
| Ventilation |
Forced from 45 ° C | ||
| Acoustic Level |
< 1-dB / 35dB
(without / with ventilation) |
||
| Warranty |
2 years |
||
| Options |
|||
| RCC-02 Remote Control and
Programming Centre |
√ | √ | √ |
| RCC-03 Rem,ote Control and
Programming Centre |
√ | √ | √ |
| CAB-RF45-2 Communication
Cable for 3 phase and parallel operation 2m |
√ | √ | √ |
| BTS-01 Battery Temperature
Sensor 3m |
√ | √ | √ |
| Data
subject to change without prior notice |
|||
| Accessories |
|||
RCC-02 |
Remote Control and Programming Centre |
||
RCC-03 |
Remote Control and Programming Centre |
||
CAB-RJ45-5 |
Communications Cable for use with RCC-02 and RCC-03 5m cable |
||
CAB-RJ45-20 |
Communications Cable for use with RCC-02 and RCC-03 20m cable |
||
| Home | Products |
Prices |
Frequently Asked Questions |
Contact Us |
SunPowerPlus Webpage |
SunPowerPlus
TradeMe
Site |
|
updated May 2010
|