AA Solar
 
34A Forge Road
Silverdale
Auckland 0932
New Zealand
Phone: 09 427 4040 or 09 427 4143
Fax: 09 427 4040
Mobile: 027 490 5901


Home
Products
Prices
FAQ's
Contact Us
Specials
SunPowerPlus Website
SunPowerPlus Trade Me Site


P O W E R M A S T E R
M P P T   S O L A R   C O N T R O L L E R S




 


SCC Series MPPT Solar Controllers (12/24/36/48 VDC)






Battery charge management, state of charge informations

Built in Battery Energy Monitor tracks Power production and consumption to calculate the energy
remaining in battery state of charge (SOC) is displayed in percent full, Amp-hours, Watt-hours
and 90days of energy-harvest history is stored in the solar charger

Continuous output Power Rating without de-rating at up to 50°C ambient temperature

Supports Flooded Lead Acid (FLA), GEL, and Absorbed Glass Mat (AGM) batteries, 2/3/4 Stage
charging with adjustable set point

Wire the PV modules in series up to 112VDC normal (140VDC Max)

Built-in temperature compensation function for safe and complete charging

Optimal Solar Maximum Power Point Tracking (MPPT)

Can be paralleled (Max. 16 sets) at will, according to your demand


Click here for pricing



PM-SCC-50AM

PM-SCC-80AM
  Max. Output Current
  (Cont. up to 50°C)
50 Amps
80 Amps
  Battery Voltages
12,24,36,48 VDC
  Max. PV Input Current
40 Amps
70 Amps
  Input Voltage Range
16~112VDC Operating
140VDC Max. Open Circuit Voltage

  Max PV Array Power
3250 Watts
5200 Watts
  Charge Regulation Modes
Bulk, Absorption, Float, Auto/Manual Equalization
  Battery Temp. Compensation
5.0 mV per°C, per 2 volt cell
  DC to DC Conversion Capability
12V Battery: 16~112VDC
24V Battery: 32~112VDC
36V Battery: 48~112VDC
48V Battery: 64~112VDC
  Display Status
Built-in 2-line, 20-character LCD with backlight
LCD status screen displays input voltage and current,
output voltage and current, charge-mode, Battery SOC
  Data Logging
Logs energy harvested for 90 days, LCD displays WH, KWH, AH
  Energy Monitor
LCD shows SOC, AH, WH, and present charge or discharge current.
A 50mV/ 500Amp shunt is required to use
  Auxiliary Relays
Two independent relays with from A (SPST) contacts for control of external devices. Contact rating is 3 Amps, 50VDC
  Operations Temp.
Full Power Output to +50°C ambient
  Standby Power
< 2 Watts
  Dimensions
267.6 x 196 x 147 mm
414.8 x 225 x 147 mm
  Weight
4.3 Kgs
7.1 Kgs

Click here for a downloadable PDF of this information



Back to Top

Updated July 2011