AA CHAMPION AGM SEALED DEEP CYCLE BATTERIES

(can also be used as STARTING BATTERIES)

  • Do you like fiddling with hydrometers and corrosive acid?
  • Do you like having to add distilled water regularly to batteries you cannot access easily?
  • Do you like the smell of lead acid fumes while charging your batteries?
  • Do you like batteries that self discharge over 30% per month?
  • Do you like throwing your money away on batteries that you have to replace every 2-3 years?
  • Do you like batteries that are wasting your expensive solar power, or are you having to run your generator for long periods because they require 115 – 125+ amp/hours charging for every 100 amp/hours that you use?
----- If your answers to the above questions are NO  -----
WE HAVE A  SOLUTION FOR YOU!!!!!
The “AA Solar Champion Deep Cycle AGM Battery
  • No hydrometers  to fiddle with, and no corrosive acid ever.
  • No maintenance - no adding water ever.
  • No acid fumes while charging.
  • Self discharge less than 1% per month!
  • 5 YEAR WARRANTY, 6 to 10 year life expectancy with proper sizing and use.
  • THE MOST EFFICIENT BATTERY AVAILABLE!
  • CAN BE MOUNTED IN ANY POSITION!
  • REAL AMP/HOUR RATED!
  • MUCH MORE COST EFFECTIVE. Much better value for your money.  
General Specifications
Specifications
Warranty Conditions
General Description

These current technology sealed batteries are designed to provide the best performance in deep cycle applications. These batteries provide these benefits with none of the disadvantages of liquid acid devices. They do not require maintenance (i.e. no water addition), do not discharge corrosive gases in significant quantities, do not self-discharge at the same rate as other batteries, and will last three to five times as long as older technology liquid acid batteries.

Gas Generation

During charging over 99% of gases generated will be recombined inside the battery. This means almost no corrosive gases are discharged. The benefits to the user are ease of location, no corrosion of terminal and interconnecting hardware, and no requirement to add water or perform maintenance testing.

Operation in any Position

With the advanced sealed and leak-proof construction, these batteries are able to be operated in any position. Once again, the benefit to the user is ease of installation and the reduction of installation costs.

Low Self-discharge

With the innovative technology incorporated in the design and manufacture of these batteries, a self-discharge rate of 2% per month or less, will be achieved at normal operating temperatures. Compare this with liquid acid technology batteries, which will self-discharge at 5% per week or greater! The Champion AGM batteries therefore give greater efficiency for the end user, providing such benefits as reduced generator fuel consumption, and better usage of expensive solar charging resources.

Long Service Life

The Champion AGM batteries are designed and manufactured to provide the longest possible service life to the end-user. In a deep-cycle application, the GM series (2 volt cells) can charge/discharge more than 1000 times to a 50% discharge level. In float applications (such as stand-by power supplies), the NP series 6 and 12 volt) batteries will achieve 3 to 5 year service life and the GM series batteries 10 to 15 years. In typical remote area power supply, motorhome and deep-cycle marine applications the expected service life of the NP 6 and 12 volt series is 5 to 8 or more years and the GM 2 volt series 15 to 20 years. (The above service life expectancies are based on a 20% capacity loss and 80% capacity remaining at the end of the stated service life.)

Highest Efficiency

The Champion AGM batteries offer some of the very best efficiencies in the market place. Typically efficiencies achieved are 95% or better. The benefits to the motorhome/remote area power supply user are distinct and economic. An efficiency of 95% means that for every 100 A/Hrs put into the batteries, 95 A/Hrs can be taken out. Liquid acid technologies typically only achieve 85% efficiencies, meaning that for 100 A/Hrs put in, only 85A/Hrs can be taken out. The economic benefits to the end-user are:- reduced generator fuel usage, shorter generator run-times and greater efficiency of expensive solar investments.

Lowest Installation Cost

As stated earlier, these batteries can be installed in places and positions not possible with liquid acid batteries. The fact they do not discharge corrosive gases means they can be placed in closer proximity to inverters etc. without harmful effects thus reducing battery cable lengths etc. and lowering installation costs. In addition, the GM series are provided with a high quality set of copper tinned interconnecting links.

Lowest Possible Maintenance Costs

These batteries are sealed and do not discharge corrosive gases and therefore do not require topping up with expensive battery water, or the laborious and somewhat dangerous procedure of hydrometer testing. The absence of corrosive gas discharge means that battery terminal fixing hardware does not corrode or require maintenance.

Best Possible Warranty

Champion AGM batteries are backed by what we believe to be the best warranty in the market. They are warranted for 5 years (NP 6V and 12V series ) & 10 years (GM 2V series ) service life, the first year being at replacement value and the remaining years pro-rata (same terms as most battery warranties only much longer). As stated above, we believe end-users in typical motorhome/remote power applications will achieve service lives of fifteen to twenty years for the GM series, and 5 to 8 years for the NP series.

Lowest Life Cycle Costs

Studying the benefits of the Champion AGM batteries will show that they provide the lowest life-cycle costs when compared with other battery technologies. We believe that considering their longer and lower maintenance, these batteries show approximately half the cost of ownership as a similar capacity liquid acid installation.

Deep Discharge Recovery

Improved design features enable the battery to provide a better recovery after repeated deep discharges. This contributes to the extended life expectancies and is important in remote area power supply applications.

No Memory Effect

The Champion AGM batteries provide no memory effect after repetitious usage or recharge. This contributes to long service life and is very important feature.
Specifications
Model
Voltage
AHrs C100*
AHrs C10*
CCA at 20°C
L(mm)
W(mm)
H(mm)
H(mm) over terminals Weight Kg
          
C6V260
6
260
200

306
168
226
226
28
C6V260D
6
260
200
T105 size
260
178
247
267
26
C6V286
6
286
220
R220 size
260
180
247
267
31
C6V390D
6
390
300
L16 size
298
178
345
365
48
C12V26
12
26
20

181
76
167
167
5.4
C12V34
12
34
26

166
175
125
125
8.4
C12V43
12
43
33
332
195
130
155
168
10.6
C12V49
12
49
38
382
197
165
170
170
13
C12V71
12
71
55
554
229
138
208
212
17
C12V104
12
104
80
806
350
167
179
179
22.5
C12V104D
12
104
80
806
260
169
208
212
22.5
C12V130
12
130
100
1008
328
171
214
220
29
C12V156
12
156
120
1210
410
176
227
227
36
C12V195
12
195
150
1512
485
172
240
240
46
C12V260
12
260
200
2016
522
238
218
222
61
C12V325
12
325
250
2520
520
269
220
224
70
C2V390
2
390
300

172
150
330
365
19
C2V520
2
520
400

210
176
330
367
25.5
C2V780
2
780
600

302
175
330
367
38.5
C2V1040
2
1040
800

410
175
330
365
51
C2V1300
2
1300
1000

475
175
330
367
61
*      C100   column is the total amp hours you can pull out of the battery over a period of 100 hours
*      C10     column is the total amp hours you can pull out of the battery over a period of 10 hours



Our AA CHAMPION BATTERY WARRANTY CONDITIONS are as follows:-

  • The batteries are installed to a proper electrical standard for low  voltage, high amperage service, and the capacity of the battery, and in a location where the average temperature is less than 35 ºC.  The capacity of the batteries chosen must be appropriate for the service intended.  I.E. Average discharge in normal usage: 20% depth of discharge 
  • A reliable Battery Monitor must be installed in the system that gives accurate charge/discharge, and state of charge information for the batteries.
  • The batteries are charged in cyclic service with the following regimen:-
          A 3 step charging regimen: Bulk, Absorption and float.
                a. Bulk charge up to 2.48 VDC per cell (14.9 VDC 12 VDC system,  29.8 VDC 24 VDC system) at 20 ºC
                b. Absorption time 1 hour for every 200 amp hour capacity.
                c. Float charge 2.28 VDC per cell (13.7 VDC 12 VDC system, 27.4 VDC 24 VDC system) at 20 ºC
  • Batteries charged in standby service are charged at 2.3 VDC per cell at 20 degrees C. and once a month  charged at 2.4 VDC per cell at the C/20 rate for 5 hours.
  • The charger must have less than 3% AC ripple in all modes.  Either switch mode type or well filtered transformer rectifier type, voltage regulated.
  • The use of Battery Temperature Sensors when the batteries are used in conjunction with solar modules/solar regulator and/or inverter/charger units, is strongly recommended for more accurate battery charging.
  • Warranty for 6 and 12 VDC batteries  is 5 years pro rata on 60 months. First year, full replacement if battery fails under warranty conditions and pro rata for a further 4 years based on 60 months and the recommended retail price at the time of warranty claim including GST.
  • Warranty for 2 VDC cells is 10 years pro rata on 120 months.  First two years, full replacement if batteries fail under warranty conditions, and a further  8 years based on 120 months and the recommended trade price at the time of warranty claim including GST.
  • Full warranty applies if used on true sinewave inverters.  If used on modified sinewave or square wave type inverters the warranty is 2 years pro rata on 6 & 12 VDC batteries and 5 years pro rata on 2 VDC cell battery banks.
  • All batteries must be returned to the authorized dealer where  purchased or to AA Solar.  2 VDC cells must be returned to AA Solar  unless prearranged with AA Solar.
  • No further or other warranties are implied or given and no liability is  accepted for any consequential damages for any reason.  The total liability or warrantee claimed is limited to no more than the sum of the original amount paid for the battery or batteries only, and does not cover any cost of installation or removal what so ever.
 


Home Products
Prices
Frequently Asked Questions
Contact Us
SunPowerPlus Webpage
SunPowerPlus TradeMe Site

updated May 2010